We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Wastewater flocculant.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Wastewater flocculant - List of Manufacturers, Suppliers, Companies and Products

Wastewater flocculant Product List

1~4 item / All 4 items

Displayed results

Aqua Nature GM, a coagulant for glass processing wastewater.

Forming strong and coarse flocks! Treatment of glass processing wastewater can be done with only one type of coagulant.

"Aqua Nature GM" is a product that can treat glass processing wastewater using only one type of coagulant. Since it uses only one chemical, it can achieve coagulation with a small amount of addition, contributing to the reduction of total running costs, including chemical costs and sludge disposal costs. It also eliminates the hassle of transporting, adding, and adjusting chemicals, thereby reducing the workload. Additionally, even in continuous wastewater treatment systems, only one reaction tank is needed, resulting in a very simple and compact wastewater treatment facility. [Features] - Treatment possible with only one agent - Space-saving treatment facilities - Reduced working time - Lower running costs *For more details, please refer to the PDF materials or feel free to contact us.

  • Glass

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Ink and adhesive-containing wastewater coagulant "Aqua Nature AL"

Can be treated with just one agent! Contributes to reducing the total running costs, including the disposal costs of generated sludge.

"Aqua Nature AL" is a coagulant for wastewater containing inks and adhesives that enables coagulation treatment without the use of multiple chemicals. The sedimentation time is very quick, allowing for a reduction in working time even in sites where small flocs previously took a long time to settle. No dissolution equipment such as quicklime or polymer coagulants is required. Additionally, even in continuous wastewater treatment systems, only one reaction tank is needed, resulting in a very simple and compact wastewater treatment facility. 【Features】 ■ Treatment possible with just one agent ■ Space-saving treatment equipment ■ Reduction of working time ■ Reduction of running costs *For more details, please refer to the PDF materials or feel free to contact us.

  • Bag making machine/slitter
  • Paper and pulp products
  • Paper Converting Machinery

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Aqua Nature GM, a coagulant for glass processing wastewater.

Reduce running costs! Eliminate the hassle of transporting, applying, and adjusting chemicals, thereby reducing the workload.

"Aqua Nature GM" is a coagulant for glass processing wastewater that can be treated with just one agent. There is no need for dissolving devices such as quicklime or polymer coagulants. Even in continuous wastewater treatment systems, only one reaction tank is required, achieving a simple and compact wastewater treatment facility. In addition, we also offer the ink and substance-containing wastewater coagulant "Aqua Nature AL" and the inorganic coagulant "Aqua Nature Plus." 【Features】 <Aqua Nature GM/Aqua Nature AL> ■ Can be treated with just one agent ■ Space-saving treatment equipment ■ Forms large flocs with a small amount of addition ■ Reduces work time even in sites that previously spent time on sedimentation ■ Contributes to the reduction of total running costs *For more details, please refer to the PDF document or feel free to contact us.

  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Can colloidal silica wastewater be treated with coagulants?

The wastewater treatment of colloidal silica can be treated with coagulants.

However, whether treatment is possible depends on factors such as particle size, so we cannot say that any material can be treated. The treatment situation also varies depending on the type of coagulant. Here is a guide on how to confirm whether treatment is possible. 1. Check the original particle size If it is around 80 nm, there is a possibility of treatment. If it becomes finer than that, treatment becomes significantly more difficult. 2. Confirm the coagulation effect First, check the effect as it is. If treatment is possible, that’s fine; if it’s difficult, move on to the next step. 3. Dilution Dilute while the coagulant is added. Check the effect while performing dilution and adding the coagulant. Dilute boldly to about 5 to 10 times and confirm at what dilution there is an effect. The alkalinity of colloidal silica wastewater can interfere with coagulation treatment, so it is also important to start with neutralization treatment in such cases. After neutralization treatment with sulfuric acid bands, coagulation treatment may significantly reduce the amount of coagulant used. First, please check the effect with a free sample or consider our free wastewater treatment test.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration